Study UK amateur radio from the circuit and the licence condition, with worked examples and original diagrams. Sources checked 28 November 2026.

What the Foundation examination asks you to do

The Foundation examination is the entry-level UK amateur-radio assessment. It asks whether you can understand a small station, use its permitted frequencies responsibly and recognise hazards. Learning only which letter was correct in a sample paper is fragile preparation: a changed voltage, a different licence-table row or an unfamiliar diagram can expose a missing idea.

The current RSGB specification lists 26 questions in 60 minutes, with 19 correct answers required. The paper draws six questions from licensing, three each from technical aspects, transmitters and receivers, feeders and antennas, EMC, operating and safety, and two from propagation. Measurements and construction is a separate higher-level section, not an extra Foundation subject. This article follows the Foundation column of Combined Syllabus v1.6b, published in March 2026, rather than importing every item from the Intermediate and Full columns.

Training is strongly recommended but a course is not compulsory. There is no prior-learning requirement or minimum examination age in the specification. The examination is in English. Check current booking and delivery arrangements with the RSGB, and apply for the appropriate Ofcom licence after the official qualification: passing a study website does not authorise transmission.

Foundation candidates should know the basic formulae: the specification does not provide a Foundation formula sheet. It does provide reference material, including licence information, band plans and frequency/wavelength information. Online candidates need the clean current EX307 reference document required by the examination instructions. Obtain it through the official syllabus page rather than using an old photocopy. Specimen band plans are assessment data and may differ from the plans used on air today.

Source: RSGB syllabus v1.6b, RSGB official guidance, RSGB official guidance.

Permission comes before a transmit button

The amateur licence permits self-training, technical investigation and non-commercial leisure communication. It is not a business messaging channel. A commercial advertisement remains commercial even if it omits prices or uses low power. The UK personal levels are Foundation, Intermediate and Full; they have different privileges. The label on a transceiver does not determine what its operator may do.

The geographical permission includes the UK, Channel Islands and Isle of Man and their territorial seas. It also covers use aboard qualifying UK, Channel Islands or Isle of Man registered ships and aircraft in international waters or airspace. Captain or person-in-control agreement is required. Airborne use has additional table restrictions. A UK Foundation licence is not routinely recognised abroad: check the destination administration before operating, including in foreign territorial waters. Adding /P or /MM does not create permission.

A licensee can allow a visitor to operate under direct supervision using the supervising callsign and conditions. The licensee remains responsible. A visiting licensed amateur using their own callsign operates under their own licence. Do not choose whichever of host and visitor has the more convenient power limit. User-service and emergency provisions exist, but they are specific licence provisions, not a general exemption for any helpful activity.

Keep the station clearly identifiable, with the callsign in a format suitable for the mode and repeated as frequently as practicable. Changes of frequency, mode, digital protocol or supervising operator are reasons to reconsider identification. RSLs are optional for Foundation and most other callsigns, but mandatory for Intermediate callsigns beginning with 2. If used, they must be right: E England, U Guernsey, D Isle of Man, J Jersey, I Northern Ireland, M Scotland and W Wales. Optional suffixes must not obscure identification or be offensive.

Amateur communication normally addresses other amateur stations. A CQ is an initial call, not permission to broadcast a programme to the public. A net of three or more amateurs first establishes communication with at least one member. Ordinary messages must not be encrypted to hide their meaning; satellite-control and defined user-service circumstances have exceptions. Publicly understood Morse code is not secret encryption.

Tell Ofcom immediately in writing when your name or address changes, and confirm details at least every five years even if unchanged. Licence breach can lead to revocation. Authorised Ofcom personnel can inspect, require modifications or restrict/close equipment in the specified circumstances. They can also require a permanent log in a particular form for a specified period. Ordinary optional logging is a different matter from a required log.

Source: RSGB syllabus v1.6b, Ofcom licence conditions.

Read a licence-table row as a complete instruction

Read four things together: frequency interval, service status, power limit and additional notes. Schedule 1 uses Table A for Foundation. The familiar 144–146 MHz row allows 25 W PEP for ordinary non-airborne operation, subject to other conditions. That is why an old statement that every Foundation station is limited to 10 W is misleading. It is equally wrong to replace it with “25 W everywhere”.

For example, the 135.7–137.8 kHz row is limited to 1 W ERP; the 2400–2450 MHz row uses 2 W and includes acceptance of ISM interference. Parts of 430–432 MHz specify ERP rather than simply transmitter power, and 431–432 MHz is unavailable within 100 km of Charing Cross. The 10 GHz entries have their own 1 W limits and service subdivisions. These examples teach how to read the table; they are not a substitute for checking its current complete text before transmitting.

A primary allocation can be shared with other primary services. Secondary use must protect primary services; it is not an extra allocation awarded to whoever transmits first. The ordinary terrestrial column and amateur-satellite column can differ within one band. Airborne operation is permitted only where the table stipulates it, with the stated 500 mW EIRP limit. Ordinary ground-based PEP is not the airborne limit.

Worked reading example: a proposed 431.5 MHz operation is 50 km from Charing Cross. The relevant row excludes the area within 100 km. Lowering power does not cure that geographic exclusion. A clear channel also does not create permission: listening and legal eligibility answer different questions.

Source: RSGB syllabus v1.6b, Ofcom licence conditions.

Current, voltage and resistance describe different things

Current is the flow of electric charge, associated with electron flow in a metal conductor, measured in amperes. Potential difference is measured in volts. Copper, brass and carbon conduct; dry plastic, rubber, glass and ceramic usually insulate. Moisture can provide a conducting path over an insulating surface. “It is plastic” is not a complete assessment of a wet installation.

A working circuit needs an energy source and a complete path. An open switch interrupts the path; it does not necessarily remove the battery voltage. In a series circuit the same current passes through every component, while the voltage drops add to the supply. In parallel, each branch sees the same supply voltage and the total supply current is the sum of branch currents. Equal voltage does not imply equal branch current.

Resistance opposes current and is measured in ohms, symbol Ω. Ohm’s law is V=IR. Rearrange it before calculating: I=V/R or R=V/I. With 8 V across a resistor carrying 0.4 A, R=8/0.4=20 Ω. If that resistance stays constant and voltage doubles, current doubles. Power, a different quantity, does not follow the same simple proportionality at fixed resistance.

Worked circuit example: two series loads share 12 V. One drops 4.5 V, leaving 12−4.5=7.5 V across the other. For two parallel receivers taking 0.6 A and 1.4 A, the supply current is 2.0 A. Do not add parallel voltages or assume that a series circuit gives each unequal resistor half the voltage. Check DC polarity before connecting electronics: a physically fitting plug may still reverse positive and negative and damage the equipment.

Source: RSGB syllabus v1.6b.

Power, units and stored energy

Power is the rate of energy transfer and is measured in watts. A current through resistance produces heat. Use P=VI for the electrical supply: a radio drawing 2.5 A at 12 V takes 30 W. This is input electrical power; it is not a statement that the antenna receives 30 W of RF. Some energy becomes heat and supports other circuitry.

Rearrange the same formula when a different quantity is missing. A 24 W load on 12 V draws I=P/V=2 A. A 36 W load taking 3 A needs V=P/I=12 V. First identify what the numbers describe, then choose the relation. Multiplying every pair of numbers because the first exercise used multiplication fails as soon as the unknown changes.

Keep units consistent. Milli means one thousandth, micro one millionth, kilo one thousand, mega one million and giga one billion. Thus 50 mA=0.050 A, 1500 kHz=1.5 MHz and 2.4 GHz=2400 MHz. With 6 V across 120 Ω, I=6/120=0.05 A=50 mA. A factor-of-a-thousand mistake can produce a plausible-looking number with the wrong unit.

A cell converts stored chemical energy into electrical energy and has a potential difference across its terminals. A battery combines cells, commonly in series. A rechargeable secondary cell uses a reversible chemical process; that does not mean its polarity can be reversed in a radio. Use the correct charger for its chemistry and follow the manufacturer’s instructions. Unwanted batteries need proper disposal, not ordinary abandonment in a shack drawer or outdoors.

Source: RSGB syllabus v1.6b.

Frequency, wavelength and digital representation

DC flows in one direction; AC reverses direction. A sine wave plots a smoothly varying alternating voltage or current against time. Frequency counts cycles per second in hertz. UK mains is nominally 50 Hz. The Foundation syllabus uses 20 Hz–15 kHz as the normal hearing range and roughly 300 Hz–3 kHz for communications audio. AF means audio frequency and RF radio frequency.

HF is 3–30 MHz, VHF 30–300 MHz and UHF 300–3000 MHz. Radio frequencies extend below and above these familiar bands. Radio wavelength λ is distance in metres, related to frequency by v=fλ. Using free-space speed 300 million metres per second gives the convenient relation λ in metres=300/f in MHz. At 150 MHz the wavelength is 2 m; a 12 m wavelength corresponds to 25 MHz. Increasing frequency decreases wavelength.

An analogue signal varies continuously. Digital representation samples it at defined intervals and represents finite values. An analogue-to-digital converter, ADC, creates the representation; a computing device processes it; a digital-to-analogue converter, DAC, produces analogue output. Digital does not mean encrypted, and two digital radio systems need not be mutually compatible.

Try a unit check before trusting a calculation: 300 divided by 150 gives metres only because MHz was used in that shortcut. Entering 150,000,000 into the same shortcut introduces a millionfold error. When uncertain, write speed as 300,000,000 m/s and frequency as 150,000,000 Hz, then cancel the units.

Source: RSGB syllabus v1.6b.

Follow information through the transmitter and receiver

A transmitter sends information using electromagnetic radiation. The microphone creates an audio signal; a microphone amplifier raises it to the level the modulator needs and limits it to the useful communication range. An oscillator supplies the RF carrier. The modulator adds the information, an RF power amplifier raises the modulated RF power, and feeder and antenna deliver it to space. An incorrectly set oscillator can put the signal outside the permitted band.

AM varies amplitude. Ordinary double-sideband AM has a carrier and two sidebands; SSB keeps one sideband. FM varies frequency. Computer audio interfaces can generate tones that carry data through a suitable transmitter input. Excessive AM depth distorts the signal and causes unwanted emissions; excessive FM deviation spreads into adjacent channels. More microphone gain is not a universal way to improve a contact.

The receiver performs the complementary tasks: antenna and feeder collect a signal, tuning and RF amplification select the wanted part, a detector or demodulator recovers information, and an audio amplifier drives headphones or a loudspeaker. A strong loudspeaker output cannot recover information already lost through a wrong RF selection or incompatible mode. These are functional blocks, not a claim that every modern radio has exactly this hardware layout.

In an SDR, incoming signals are digitised and software performs frequency separation, filtering and demodulation. An SDR transmitter generates modulated signals in software, with conversion and RF hardware delivering the result. Software changes implementation, not the need for suitable input signals, output levels, antenna loads or lawful operation. A power amplifier still needs an appropriate load; a severe mismatch can damage it.

Original functional diagram from microphone through transmitter and radio path to receiver and speaker

In our waveform drawing, A is a constant unmodulated RF carrier. B changes envelope amplitude while retaining the basic carrier spacing: AM. C changes cycle spacing at constant amplitude: FM. D switches the carrier into bursts: keyed CW. An audio waveform is much slower than the RF carrier. Look at what changes, rather than the darkness of a printed line.

The voltage–time comparison below shows why the time axis matters. Trace A has four cycles in 4 milliseconds: 4/0.004=1000 Hz, an audio-frequency signal. Trace B has four cycles in 4 microseconds: 1 MHz, a radio-frequency signal. An audio signal and an RF carrier may share a sinusoidal shape but differ greatly in frequency.

Original comparison: four cycles across 4 milliseconds in A and 4 microseconds in B

Four labelled original RF traces: steady carrier A, amplitude variation B, frequency variation C and keyed bursts D

Source: RSGB syllabus v1.6b.

Recognise symbols before tracing a circuit

The official Foundation material includes a small standard symbol vocabulary. Learn the shape and the job together: a cell supplies energy, a battery combines cells, a resistor opposes current, a lamp emits light and heat, a fuse interrupts excessive current and a switch opens or closes a path. The LED symbol includes outward light arrows. Antenna, earth, microphone and loudspeaker symbols tell you where signals enter or leave a block diagram.

Our original symbol drawing uses A cell, B battery, C resistor, D incandescent lamp, E fuse, F switch, G antenna, H earth, I microphone, J loudspeaker and K LED. The distinction between C and E is particularly useful: the fuse symbol has the conducting line through its body. Recognising a symbol does not by itself qualify someone to work on mains equipment. Use the official Table 1 as additional recognition practice because drawings may vary in orientation and style.

Original component-symbol sheet labelled A through K for cell, battery, resistor, lamp, fuse, switch, antenna, earth, microphone, speaker and LED

Source: RSGB syllabus v1.6b.

Feeders, connectors and matching

Coaxial feeder has a centre conductor surrounded by a screen and is unbalanced. Twin feeder is balanced: its two conductors carry equal and opposite signals. Coax is widely used because the screen reduces unwanted coupling, but screening does not mean zero loss. Loss affects both transmitted and received signals, increases with length and generally rises with frequency. At VHF/UHF, compare the specified loss per unit length carefully.

A balanced dipole fed by unbalanced coax normally needs a balun at the transition. Connectors must suit the RF system, and the braid must make the intended connection. Learn BNC, N, SMA and PL259 from the official Table 2 illustrations. BNC uses a bayonet coupling; N and PL259 are larger threaded designs, while SMA is a small threaded design common on handheld equipment. Physical resemblance alone does not prove compatibility: connector type, dimensions and variants still matter.

In the original simplified connector views below, A is BNC, B N, C SMA and D PL259. The views emphasise coupling and contact geometry and are not to a common scale. Use the official Table 2 illustrations and real connectors to reinforce recognition.

Original simplified connector views labelled A BNC, B N, C SMA and D PL259

The antenna feed point has an impedance that depends on antenna dimensions and frequency. It should suit the feeder and transmitter. A mismatch reflects some energy back down the feeder and creates standing waves. An SWR meter indicates the match; a high reading at the transmitter points toward the antenna/feeder system, not automatically the transmitter. SWR much greater than 2:1 can threaten the output stage.

An antenna matching unit, AMU or ATU, transforms the load seen by the transmitter. It can allow useful power transfer without an unsuitable transmitter load. It does not make every antenna intrinsically resonant, remove all cable loss or guarantee efficient radiation. Worked diagnosis: if an antenna formerly worked and now shows high SWR, inspect the connector, feeder and antenna before assuming the oscillator or audio amplifier is faulty.

Source: RSGB syllabus v1.6b.

Antenna shape, direction and radiated power

An antenna converts electrical RF energy into radio waves and works in reverse on reception. A horizontal dipole normally gives horizontal polarisation; a vertical element gives vertical polarisation. Matching polarisation matters especially on direct VHF/UHF paths. HF ionospheric propagation can change polarisation, making the simple local-path rule less decisive.

A half-wave dipole has a total length roughly half the wavelength, with two arms around a central feed. At a wavelength of 10 m, its ideal total length is 5 m, each arm 2.5 m, before practical end-effect adjustment. A quarter-wave ground plane uses a vertical radiator and radial return structure; a five-eighths-wave vertical is longer. An end-fed wire is fed at one end. A Yagi has a driven element and parallel parasitic elements along a boom. The same principles apply at HF and VHF; dimensions change with wavelength.

A horizontal dipole has strongest horizontal radiation broadside to the wire and nulls along its axis. A vertically mounted dipole is approximately omnidirectional in the horizontal plane, as are quarter-wave and five-eighths-wave verticals. Omnidirectional in azimuth does not mean equal radiation in every three-dimensional direction. A Yagi concentrates radiation into a preferred direction, with smaller rear or side responses.

Recognise the physical form as well as its radiation pattern. In the original shape drawing, A is a centre-fed half-wave dipole, B a quarter-wave ground plane, C a Yagi, D an end-fed half-wave wire and E a five-eighths-wave vertical. The feedpoint and parasitic elements help distinguish the forms; the two verticals require their labelled electrical lengths because drawings need not share a scale.

Original antenna forms A centre-fed dipole, B quarter-wave ground plane, C Yagi, D end-fed wire and E five-eighths-wave vertical

Original horizontal pattern sketches showing dipole broadside lobes and axial nulls, and a Yagi forward main lobe

Gain is concentration, not creation of energy. Gain relative to a half-wave dipole leads to ERP; gain relative to an isotropic radiator leads to EIRP. The syllabus equivalence is 10 W EIRP≈6.1 W ERP. Do not compare a transmitter-output number with an ERP limit without considering the feeder and antenna.

Worked ERP example: 5 W reaches an antenna with linear gain 4 relative to a dipole. ERP=5×4=20 W. The supplied decibel conversion table uses approximately 3 dB=×2, 6 dB=×4 and 10 dB=×10. If 3 W reaches a 3 dBd antenna, ERP≈6 W. Multiply by the linear factor, not the number 3 merely because the gain is written as 3 dB.

Source: RSGB syllabus v1.6b.

Why a radio path works today and fails tomorrow

Radio waves normally travel in straight lines, spread out and become weaker, but can also reflect, refract and diffract. Reflection redirects at a boundary, refraction bends a path as propagation conditions change, and diffraction allows some energy around obstacles. None guarantees that an obstructed link will work.

The ionosphere contains ionised gases approximately 70–400 km above Earth, mainly produced by solar ultraviolet radiation. Much HF long-distance communication depends on refraction returning waves toward Earth. The useful frequency changes with time of day, season and solar activity. A band is “open” when it supports useful skywave propagation, not when it is legally unrestricted or unoccupied.

Ordinary VHF/UHF propagation is mainly in the troposphere below the ionosphere; these frequencies normally pass through the ionosphere. Range is generally not much beyond line of sight. Hills produce shadows, buildings weaken signals passing through them, and increasing frequency generally makes these local-path limitations more significant. Sporadic E and atmospheric ducting can create much longer paths. Rain, hail and snow can attenuate UHF and higher-frequency signals.

Antenna height, gain, path clearance and transmitter power all matter. Raising an antenna can improve both reception and transmission; increasing transmitter power helps only the outgoing direction. Outdoor placement generally performs better than an obstructed indoor installation. Before buying more power, identify whether the difficulty is path clearance, polarisation, feeder loss or interference.

Source: RSGB syllabus v1.6b.

EMC: find the route of the unwanted signal

Electromagnetic compatibility means equipment can coexist without unacceptable interference. Immunity is an affected device’s ability to work in the presence of RF. A transmitter may disturb nearby audio or television equipment; a receiver may also suffer noise from local electronics. A licensed transmitter is not automatically innocent, and a coincident noise event is not automatically proof of its guilt.

More power generally increases the chance of interference. AM and SSB are often more troublesome than FM and some HF data modes because the unwanted signal can be detected in susceptible circuitry. RF can enter through mains wiring, antenna down-leads and telephone leads, and at VHF/UHF directly into internal circuits. The receiver’s selected channel is not the only route into equipment.

Suitable external chokes and filters can improve immunity. Put them close to the affected equipment to avoid leaving a long unfiltered pickup lead. A correctly rated screened dummy load replaces the antenna with a suitable resistor. If a symptom persists while transmitting into it, investigate conducted RF on power or interface leads. A dummy-load test narrows the possibilities; it is not conclusive proof that no RF escapes anywhere.

Place antennas high and away from houses where practicable. At HF a balanced horizontal dipole is often a better starting point than an end-fed wire close to building wiring. An RF earth aims to reduce unwanted RF in the mains earth system; it must not replace or remove protective earthing. Get competent advice before altering earth arrangements.

For vehicle installations, the owner must ensure compatibility with vehicle electronics and safety, obtain professional advice and consider insurer disclosure. Start testing while stationary with vehicle electronic systems operating, before any road test. Ignition and charging systems can themselves disturb radio reception.

Good neighbour relations make diagnosis easier. Compare the station log with a complainant’s timed record, include mode and operating conditions, and arrange cooperative tests. Correlation suggests where to look; controlled changes help test the hypothesis. The RSGB EMC team and experienced clubs can advise, and Ofcom has a role in interference cases. A calm technical investigation is more useful than arguments about whose equipment is newer.

Source: RSGB syllabus v1.6b.

Make a contact without taking over the band

Listen before transmitting, then ask whether the frequency is in use. One side of an existing conversation may be inaudible to you. A short identified CQ followed by listening invites a contact. On a VHF/UHF calling channel, establish contact, agree a suitable clear working frequency and move away. A centre of activity helps people find an activity; it is not exclusive ownership of a frequency.

The conventional suffixes are /A alternative address, /P portable, /M mobile and /MM maritime mobile. They describe circumstances but do not extend your legal permissions. Use the standard phonetic alphabet consistently: Alfa, Bravo, Charlie, Delta, Echo, Foxtrot, Golf, Hotel, India, Juliett, Kilo, Lima, Mike, November, Oscar, Papa, Quebec, Romeo, Sierra, Tango, Uniform, Victor, Whiskey, X-ray, Yankee, Zulu.

A useful log records date, UTC time, mode and the other station’s callsign for QSL and contest purposes, with other relevant details. UTC provides one common time reference across time zones. Logs also help interference investigations. Avoid music, offensive and threatening language. If another station behaves badly, do not amplify the problem by rebroadcasting or escalating it; disengage and seek appropriate advice.

Band plans coordinate modes and activities within the legal allocations. Narrow modes such as CW and data are normally toward the lower end of many bands. The general SSB convention is lower sideband below 10 MHz and upper sideband above it. Avoid beacon segments and protect satellite and repeater activity. A plan does not grant a frequency missing from your licence, and a factory channel memory does not prove permission.

For an examination question explicitly based on a supplied specimen, use that specimen. For actual operation, use the current rules and applicable plan. The distinction matters because an exam reference can deliberately remain stable while live allocations or operating arrangements change. After installing or changing a station, test that it does not cause undue interference; successful contacts alone do not establish that.

Source: RSGB syllabus v1.6b.

Repeaters, digital modes and reports

Repeaters mainly extend mobile coverage by receiving on one frequency and retransmitting on another. The frequency offset separates input and output. Users transmit on the input and listen on the output. Do not use repeater frequencies for arbitrary simplex contacts. A CTCSS tone enables the intended access or squelch response; it is neither encryption nor extra RF power. Different repeaters may need different tones.

Leave suitable gaps so the repeater can reset and another station can join. A time-out discourages excessively long transmissions. Analogue FM and digital-voice users should check for other modes, but those checks are not completely reliable: a squelched or incompatible receiver can hide activity. Silence in the loudspeaker is not always silence on the channel.

A computer interface or replacement microphone must provide correct PTT behaviour and suitable audio levels. Connector fit alone is insufficient. Digital voice and digital data require compatible systems and appropriate equipment. A borrowed DV radio may transmit its owner’s callsign in embedded data; set the identity appropriately for your operation.

RST means readability, signal strength and tone. Readability runs from 1 to 5, strength and tone from 1 to 9, with higher numbers better. Thus the 5 in 579 is the best readability category, not five watts. Voice reports commonly use readability and strength. Amateur satellites use designated frequencies within amateur bands: protect those segments from ordinary terrestrial contacts.

Source: RSGB syllabus v1.6b.

Electrical and workshop safety

High voltage can produce dangerous body current and electrocution. High available current can overheat conductors and cause fire, even from a low-voltage battery. A battery capable of starting an engine is not harmless because its nominal voltage is much lower than mains. Protect connections against short circuits and charge only as the manufacturer specifies.

A fitted safety earth must not be removed. In current UK mains wiring, brown is live, blue neutral and green/yellow protective earth. Recognise the correct plug connections for the examination, but do not treat a quiz answer as authority to undertake work beyond your competence. Follow manufacturer instructions, isolate every supply before internal work and consider stored energy that may remain after disconnection.

A fuse contains a thin element designed to melt and interrupt excessive current. Fit the specified rating and investigate why it blew; a larger fuse or improvised bridge hides the symptom while removing protection. A suitable RCBO combines overcurrent protection with residual-current protection, commonly responding to about 30 mA earth leakage. A normal fuse needs much larger fault current and is not equivalent shock protection. Contact with both live and neutral can still be fatal; no protective device makes careless contact safe.

Use a clearly marked master switch whose location is known to others. In an electrical accident or fire, first switch off the power; do not touch an electrically connected casualty before isolation. For batteries, use the right charger and chemistry-specific procedure. Lithium batteries can cause fire or explosion if mishandled.

Tools need care whether powered or manual. Wear eye protection against drilling swarf and solder/flux splashes. Use a soldering-iron stand to prevent accidental contact with the hot tip and provide effective ventilation for fumes, especially around people with asthma. Eye protection does not replace secure workholding, and a stand does not replace ventilation.

Source: RSGB syllabus v1.6b.

Height, RF exposure and a temporary station

Antenna erection is a mechanical task as well as a radio task. Have help and at least one adult present. Use ladders at the basic four-to-one rise-to-base ratio, secure them and avoid overreaching. For 4.8 m of vertical rise, the base distance is 4.8/4=1.2 m. This arithmetic is only one part of safe setup, not a complete work-at-height plan. Use tool belts or similar control and appropriate hard hats where falling objects are a risk.

Keep masts, antennas, ladders and their possible fall paths well away from overhead power lines. A lethal arc can occur without direct contact. Secure elevated wires and structures. Particularly high antennas may need specialist lightning protection advice; local authority building departments may be able to advise. An RF earth is not automatically a lightning protection system.

RF exposure and EMC are different. The principal Foundation health effect is heating of body tissue, with the eyes particularly susceptible. Do not look into a potentially active microwave waveguide or stand close in front of a high-gain transmitting antenna. Keep accessible RF conductors away from accidental contact during transmission; small low-power handheld equipment is a distinct case in the syllabus. Government health guidance and ICNIRP provide the exposure framework.

The Ofcom licence’s EMF condition protects members of the public where they are or can reasonably be expected during transmissions. Relevant equipment is equipment authorised above 10 W EIRP or 6.1 W ERP. Keep records showing how compliance is achieved, including a justified conclusion that operation below the threshold needs no further action. The operator/licensee and specified occupational roles are outside the licence’s definition of general public, but that does not mean their exposure is harmless or other safety duties disappear. Site assessment depends on radiated power, antenna, frequency and access; this article does not give a universal safe distance.

Temporary premises introduce new conditions: damp ground, provisional mains connections, trailing cables and unfamiliar visitors. Reassess risks, protect cable routes, use correct fusing and suitable RCBO protection, and make no live internal adjustments. Keep headphone volume sensible. Safety belongs to everyone: notice hazards, warn others and report or address them appropriately. Ask for competent advice whenever the safe arrangement is uncertain.

Source: RSGB syllabus v1.6b, Ofcom licence conditions.

A preparation cycle you can repeat

First read the official Foundation column and obtain the current reference booklet. Work through the electrical quantities and radio signal path until you can explain each in ordinary words. Then practise the supplied tables: say the frequency, status, power measurement and exception aloud before deciding whether an operation is permitted. This makes table-reading a skill instead of a memory contest about one familiar band.

Next work through original calculations without looking at choices. Write the formula, insert values with consistent units and check whether the result is physically reasonable. Learn symbols, waveform changes, antenna shapes and connector illustrations from both this article and the official reference material. Our drawings are independent teaching illustrations; connector recognition here should be supplemented by the official Table 2 views.

Use the RSGB Foundation study test to find weak topics. It contains 185 questions: 170 single-answer choices and 15 numerical entries. It presents the whole bank in shuffled order with no timer or qualification threshold. Numerical questions specify the requested unit; enter just the number, using a point or comma as the decimal separator. Read the explanation even after a correct guess, and return to the named objective when the reason is unclear.

Finally use official specimen papers to practise the actual 26-question, 60-minute format and its section balance. This bank deliberately supplies a larger learning set and independent calculations; it is not a cloned official paper or a guarantee of passing. Arrange supervised practical experience and safety instruction where appropriate. Before the real assessment, check the current edition and booking instructions; before transmitting, check the actual licence and operating conditions.

Source: RSGB syllabus v1.6b, RSGB official guidance, RSGB official guidance.