Which FCC examination this guide prepares you for
The General Radiotelephone Operator License, or GROL, is a US commercial radio qualification. Its written requirements are commercial Elements 1 and 3. Element 1 concerns maritime radio law and operating practice; Element 3 concerns the electronics and techniques used to adjust, repair and maintain aviation and maritime radio equipment. The amateur General license also has an examination called Element 3, but it is a different qualification and syllabus.
Use this guide with our original GROL study test. The material covers the published topic framework, explains the underlying reasoning and supplies additional calculation exercises. It is not an official FCC pool, an approved examination or a practical-maintenance qualification. The separate Ship Radar Endorsement requires Element 8; the GMDSS operator and maintainer routes have different additional requirements.
The licensing and examination basis is 47 CFR Part 13, especially §§ 13.201–13.215. Checked on 28 November 2026: the retrieved Part 13 page displayed currency through 19 November 2026; maritime and aviation rule pages displayed 25 November 2026. A retrieval date is not a promise that no later amendment exists.
The real examination and our learning format
A Commercial Operator License Examination Manager, or COLEM, administers the examination. The current Mariners Learning System GROL examination page lists 24 multiple-choice questions for Element 1 and 100 for Element 3, with 75% required in each: 18 and 75 correct answers respectively. Passing one element does not compensate for failing the other. That examiner offers two hours for each online element. Treat this as its advertised arrangement, not a universal time limit for every examiner.
Before booking, check the COLEM’s identification, registration, calculator, reference-material, proctoring and accessibility instructions. Do not assume that a calculator or an open book permitted during study will be allowed during the examination. Follow the current application process after passing; an AnyTest result is not a proof-of-passing certificate.
The linked bank has 163 questions: 135 single-answer choices and 28 numerical exercises. It shows the full bank in shuffled order, without a timer or pass threshold. The numerical exercises develop reasoning even though they do not copy the official multiple-choice format. Enter the requested number without units or thousands separators; use a point or comma for decimals. Read any stated rounding instruction.
How to use the published topic framework
The official Element 1 file organizes its material into 24 key topics across regulations, procedures, equipment operation and other equipment. The commercial Element 3 file has 100 key topics across 17 subelements, from electrical principles through safety. We use those headings to prevent convenient topics from crowding out less familiar ones.
The copies examined were archived FCC publications bearing approval on 25 June 2009. Live FCC downloads were unavailable during preparation. Archive captures establish the contents of those copies, not that they are the latest authorized pool in November 2026. The current Part 13 subject scope and a current examiner’s GROL offering independently establish the examination. Confirm the currently authorized question pool with your COLEM before taking it.
Older topic lists contain legacy satellite services and equipment. Learn the engineering distinction they illustrate, but do not treat every historical terminal name as a service available for a new installation. For actual equipment and operation, use current rules, current service information and the equipment manual. The original questions here are not a word-for-word substitute for studying every authorized examination question.
Element 1: authorization, watches and the radio record
Keep three things separate: approval of the equipment, authorization of the station and qualification of the operator. A transmitter that can tune a frequency is not thereby approved for maritime use. When the applicable certification rule requires it, the relevant evidence is FCC authorization for Part 80 operation. A technician’s license or a ship inventory does not certify the transmitter design. See § 80.203, including its exceptions.
A watch is an operating duty, not merely possession of a receiver. For the duplicated GMDSS installations covered by § 80.93, at least one of each duplicate DSC or satellite installation must be on and maintaining the proper watch while underway. The correct watch arrangement depends on the vessel and its installation; do not turn a narrow rule into a universal instruction for every boat.
A log preserves what happened, when and under whose responsibility. Under § 80.409, correction preserves the original entry: its author strikes through the error, initials and dates the correction; electronic logs use the corresponding dated electronic method. Ordinary retention is generally two years from entry, distress/disaster entries three years, and investigations or claims can require longer. The public coast log also records equipment failures and incidents delaying communication. Do not wait for the repair invoice before documenting a relevant failure.
Element 1: priority and the next transmission
Start by classifying the event. MAYDAY means distress: grave and imminent danger requiring immediate assistance. PAN PAN introduces urgency concerning a vessel, aircraft or person without necessarily meeting that distress condition. SECURITE introduces safety information such as a navigational warning. The priority order is distress, urgency, safety, then other traffic; the first station to speak does not acquire priority over a later distress call. See § 80.91 and the distress, urgency and safety provisions.
Example: a ship is taking water rapidly and needs immediate rescue; another wants medical advice for a stable patient. The first situation calls for distress priority. The useful message identifies the vessel, gives position, describes the emergency and says what help is needed. A complete inventory of radio equipment is less useful than a usable position and a clear account of danger. If the medical situation deteriorates into grave and imminent danger, reassess its priority rather than retaining a label mechanically.
For routine calls, listen before transmitting, avoid an exchange already in progress and move from the calling channel to an appropriate working channel once contact is established. When communicating with a coast or government station, follow its ordinary traffic instructions, subject to the distress exception. Bridge-to-bridge communication serves navigational coordination, not passenger correspondence. Read § 80.92 and § 80.94.
Element 1: controls, faults and safety equipment
Squelch controls when receiver audio is muted. Set too high, it hides weak calls; microphone gain cannot recover them because it controls transmitted audio. A US/international channel switch changes the relevant channel plan, not the antenna polarization. Channel 70 is DSC signaling, not an alternative voice channel. On HF SSB, receiver incremental tuning can clarify slightly offset reception without deliberately changing the assigned transmit frequency. An antenna tuner transforms impedance; it does not eliminate feed-line loss or authorize a new frequency.
Testing is not permission to occupy a distress channel at will. § 80.101 specifies radiotelephone test identification, listening and timing. If a station responds WAIT, suspend at least 30 seconds before the prescribed renewed call and listening. A malfunctioning transmitter must be taken off air until corrected, apart from the rule’s immediate-safety exception: § 80.90. Reducing power does not necessarily cure distorted or off-frequency emissions.
GMDSS equipment has different jobs. A 406 MHz EPIRB alerts the rescue system. A conventional X-band radar SART helps a searching radar locate survivors; an AIS-SART is a different device. Survival-craft VHF supports nearby communication, and its designated emergency battery must retain emergency capacity. An independent reserve source keeps the required radios available after the main and emergency sources fail. An unconnected spare battery is not automatically an adequate reserve installation.
NAVTEX receives maritime safety information; international English-language service uses 518 kHz. Station, subject and message identifiers support selection and duplicate handling. Read the National Weather Service NAVTEX explanation and equipment instructions rather than assuming every unwanted message can safely be disabled. After an accidental EPIRB alert, stop the false transmission and notify the rescue authority: switching off the beacon cannot retract a message already received. These operating distinctions follow the Element 1 equipment topics; practical deployment requires training with the actual equipment.
Electrical principles: identify the quantity before calculating
Voltage is potential difference; current is charge flow; resistance relates them in a resistive model. Use I = V/R, P = VI and P = I²R = V²/R with consistent units. A milliampere is 0.001 A, a microfarad is 0.000001 F and a megahertz is 1000000 Hz. Unit mistakes often produce numbers that look plausible but differ by a thousand or a million.
Example: a 15 Ω resistor across 30 V takes 2 A and dissipates 60 W. The arithmetic says nothing about whether a particular physical resistor can safely dissipate that heat. Its power, voltage, temperature and mounting ratings must also be suitable. In a simple resistive source model, maximum load power occurs when load resistance equals source resistance, but this condition wastes half the resistive power in the source; maximum power and maximum efficiency are different objectives.
Capacitors store energy in electric fields and inductors in magnetic fields. Inductance opposes changes of current; interrupting a coil’s current can produce a high voltage. Resistance depends on material, length and cross-sectional area. At RF, skin effect crowds current toward the surface, increasing effective resistance. Dissimilar metals in a conducting environment can create galvanic corrosion; a good DC conductor is not automatically a suitable mechanical or corrosion-resistant connection.
For sinusoidal AC, apparent power is Vrms × Irms in volt-amperes. Real power includes power factor. For a sine wave, Vrms = Vpeak/√2 and Vpeak-to-peak = 2Vpeak. A square wave contains harmonics, so do not apply sine-wave conversion factors to every waveform. These principles are the foundation of Element 3 key topics 1–13.
Time constants, impedance and transformer ratios
An RC time constant is R × C in seconds. A charging capacitor reaches about 63.2% of its final change after one time constant, while a discharging capacitor retains about 36.8% of its starting voltage. After two constants the remaining discharge fraction is about 13.5%, not 26.4%; exponential change does not remove the same voltage amount each interval.
Example: 100 kΩ and 20 µF give τ = 100000 × 0.000020 = 2 s. An initially charged 10 V capacitor discharging through that resistor has about 3.68 V after 2 s and 1.35 V after 4 s. This ideal model omits leakage and loading. For combinations, add capacitors in parallel; use reciprocal addition in series. For uncoupled ideal inductors, the familiar series sum applies.
Reactance retains phase information. Write a series impedance as R + j(XL − XC), with XL = 2πfL and XC = 1/(2πfC). A 12 Ω resistance and net 5 Ω inductive reactance give magnitude √(12² + 5²) = 13 Ω, not 17 Ω. Parallel networks require adding admittances, the reciprocals of impedance. At series resonance, opposite reactances cancel at the input; parallel resonance instead gives a high input impedance in the usual low-loss model. Large internal reactive currents or voltages can still exist.
An ideal transformer’s voltage ratio follows turns ratio; impedance ratio follows its square. Matching 800 Ω to 200 Ω therefore needs a 2:1 turns ratio, not 4:1. Keep the direction explicit. For regulation calculations, state the denominator: using full-load voltage, a supply falling from 22 V to 20 V has (22 − 20)/20 × 100% = 10% regulation. See topics 14–18, 21 and 29.
Components: predict the failure, not just the symbol
A rectifier diode’s forward-current and reverse-voltage limits matter separately. A Zener can provide a voltage reference within its specified operating conditions. A reverse-biased varactor supplies voltage-dependent capacitance for tuning; a PIN diode can provide controlled RF resistance for switching or attenuation. An LED emits light under suitable forward bias and needs current control. An optocoupler sends a signal across an insulating optical barrier, which a grounded resistor divider cannot provide.
Example: a 9 V supply, LED drop of 2 V and target current of 14 mA require R = (9 − 2)/0.014 = 500 Ω in the ideal model. Check resistor power, LED limits and available component tolerances before a real design. Reusing a resistor merely because the LED lights is not a specification check.
For a bipolar transistor, β relates collector to base current in the applicable operating region. An emitter follower provides current buffering with voltage gain near one. In saturation, both base-emitter and base-collector junctions are forward biased; that is not the forward-active condition used for linear amplification. An ordinary SCR latches and remains on until current falls below its holding value; removing the gate pulse alone does not necessarily turn it off. A triac supports bidirectional AC control. FET and CMOS gates require careful electrostatic handling.
Coupling capacitors pass suitable AC while separating DC bias; bypass capacitors provide a local AC path toward signal ground. An open coupling capacitor can remove signal transfer while both stages still show reasonable DC bias. Linear regulators dissipate excess voltage across a pass device; switching regulators reduce loss by operating switches mostly on or off, while introducing filtering and electromagnetic-compatibility considerations. Quartz crystals exploit piezoelectric resonance for stability. These distinctions cover topics 19–28.
Circuit blocks and digital logic
Negative feedback lets an op-amp’s external network set a useful closed-loop response. An ideal inverting stage has gain −Rf/Rin: 30 kΩ feedback and 10 kΩ input resistance give −3, provided the output stays within its linear range. Without appropriate feedback, a small input difference may drive the output toward a limit, as in comparison. Read a schematic by following signal and DC paths separately. A series capacitor followed by a resistor to ground is a high-pass arrangement when the output is across the resistor.
A PLL compares a divided oscillator signal with a reference, filters the error and controls a VCO. A mixer produces sum and difference components; it does not select the wanted result by itself. A filter after the mixer chooses the useful band. Oscillation requires suitable feedback phase and enough start-up loop gain; steady amplitude is then limited by the circuit’s behavior.
AND, OR, NAND, NOR, NOT and XOR describe truth-table operations. For example, NAND gives zero only when both inputs are one; XOR gives one when its inputs differ. Distinguish a physical voltage from its logical interpretation: negative logic assigns zero to the higher level. A voltage between a device’s guaranteed LOW and HIGH thresholds is undefined, not a useful third binary state.
Flip-flops store bits; counters divide and count clock events. A monostable produces one timed pulse, an astable runs repeatedly and a bistable retains either of two states. Eight independent bits need eight one-bit storage elements, even though three bits can encode eight possible states. DRAM needs refresh; SRAM uses stable powered cells; nonvolatile memory such as EEPROM retains calibration after power removal. A watchdog detects missing software activity and can initiate recovery. ADCs and DACs convert between analog values and digital representations. Review topics 29–40.
Receivers: follow the signal and the unwanted signal
A receiver must recover a weak wanted signal while tolerating stronger unwanted ones. Noise figure expresses signal-to-noise degradation; selectivity describes frequency discrimination; dynamic range concerns the range between useful weak signals and unacceptable strong-signal effects. More front-end gain can improve a weak-signal situation yet worsen overload. A very strong off-channel signal can matter even when its audio is not selected.
In a superheterodyne, an RF signal mixes with a local oscillator to produce an IF. Both sides of the oscillator can generate the same difference frequency. Example: for 120 MHz reception with a 130 MHz LO and 10 MHz IF, a 140 MHz signal is the image because it also differs from the LO by 10 MHz. Reject it before the first mixer; the IF filter cannot distinguish two inputs already converted to the same IF.

This is a teaching diagram, not the schematic of a particular radio. A high first IF can improve image separation, while a lower later IF can make narrow filtering convenient. A filter that is too broad admits noise and adjacent signals; one that is too narrow removes wanted modulation.
Butterworth response is maximally flat in its passband. Chebyshev Type I accepts passband ripple for a sharper transition at a given order. An SSB product detector mixes with a restored carrier; an FM discriminator recovers frequency deviation. Audio de-emphasis complements transmitter pre-emphasis. CTCSS opens squelch for the selected tone but does not encrypt speech. Cross-modulation and intermodulation are consequences of nonlinearity, not ordinary tuning errors. See topics 41–50.
Transmitters and modulation: preserve the information
Conduction angle distinguishes amplifier classes: A conducts throughout the cycle, B for half, AB for more than half but less than all, and C for less than half. A tuned output can reconstruct a sinusoidal RF waveform from pulsed device current, so device conduction and antenna waveform are different observations. Varying-envelope signals such as SSB need appropriate linear amplification; excessive drive produces intermodulation and unwanted emissions.
A balanced modulator suppresses the carrier while producing sidebands. Filtering or other suitable methods select one sideband for SSB. A two-tone test gives a controlled varying envelope and identifiable distortion products; it does not recreate every speech pattern. Peak envelope power is the RF-cycle average at the envelope peak, not the ordinary long-term voice average.
Example: at an envelope peak, an RF sine wave has 80 V peak across 50 Ω. Its RMS voltage over the RF cycle is 80/√2 V, so PEP is 80²/(2 × 50) = 64 W. If 80 V had been peak-to-peak, the answer would be four times smaller. Write down the voltage convention before using the formula.
For single-tone FM, modulation index is peak deviation divided by modulation frequency. Carson’s estimate is B ≈ 2(Δf + fm). With 2.5 kHz deviation and 2 kHz highest modulation frequency, the estimate is 9 kHz. This calculation is not a regulatory bandwidth authorization. PWM varies pulse duration; pulse-position modulation varies timing; pulse-amplitude modulation varies amplitude. Output L, pi and related networks match impedances and can help suppress harmonics; isolators and filters can reduce coupling between colocated transmitters. See topics 51–59 and the applicable maritime or aviation emission rules.
Power sources, antennas and feed lines
Series batteries add voltage while preserving the ideal ampere-hour rating of identical units; parallel batteries add capacity at unchanged voltage when correctly matched and connected. Energy in watt-hours is voltage times ampere-hours. Example: 12 V and 20 Ah give an ideal 240 Wh; an 80 W load would use that in 3 hours. Real endurance depends on aging, temperature, discharge rate, usable capacity and conversion loss. This estimate cannot certify a reserve installation.
Charging lead-acid batteries requires attention to ventilation and ignition sources. Motors and generators convert energy through electromagnetic action. A series DC motor can overspeed if unloaded; a generator’s induced voltage depends on flux and motion. Practical service needs the manufacturer’s protection and maintenance procedures, not just a circuit formula.
Wavelength is c/f. Antenna dimensions, loading and nearby structures affect resonance, impedance, bandwidth and pattern. A half-wave dipole has current minima near its open ends and a current maximum near the center in the simple model. Radiation resistance represents radiated power as an equivalent resistance; it is not simply a measured wire resistance.
Feed-line characteristic impedance, attenuation and velocity factor describe different properties. A matched line has VSWR 1:1; a low meter reading alone does not prove a lossy system radiates efficiently. Velocity factor changes wavelength along the line. Decibels add gains and subtract losses, but remember the reference: dBd uses a dipole, dBi an isotropic radiator. With approximate 3 dB steps, 40 W through 3 dB loss and into 6 dBd gain gives 40 ÷ 2 × 4 = 80 W ERP, not EIRP. Review topics 60–67.
Aircraft systems: keep bearing, range and guidance distinct
VOR gives a radial, a magnetic bearing from the station; a radial is not the aircraft’s heading. DME measures radio travel time and gives slant range. Directly overhead, an aircraft at altitude still has nonzero DME distance. ILS localizer supplies lateral guidance and glide slope vertical guidance. NDB/ADF information can be disturbed by propagation and interference, including nighttime reception effects. These distinctions and operational limitations are explained in the FAA Aeronautical Information Manual, Navigation Aids.
A conventional secondary-surveillance transponder receives interrogation on 1030 MHz and replies on 1090 MHz. SELCAL alerts a crew to a selective call; it does not provide bearing or range. An ELT supports emergency alerting and locating. Antenna polarization and placement affect communication, and airframe shielding can degrade an otherwise serviceable system. Read the aircraft and equipment documentation before testing: a bench principle is not permission to radiate near people or other equipment.
For GROL preparation, connect each block to what it measures or communicates. Draw one line for bearing, another for distance, another for lateral or vertical deviation. This prevents the plausible but incorrect substitution of “navigation aid” for a specific function. The Element 3 aircraft topics 68–73 and Part 87 provide the examination and regulatory context. This section is not flight instruction.
Measurement, installation and fault isolation
A measurement changes the circuit unless the instrument’s loading is negligible. A low-input-resistance voltmeter can pull down a high-resistance divider. A series multiplier extends a voltmeter range; a parallel shunt carries excess current around an ammeter movement. A suitable oscilloscope probe reduces loading, but its attenuation and compensation must be accounted for.
An oscilloscope shows voltage against time; a spectrum analyzer shows amplitude against frequency. A counter measures frequency against its time reference. A modulation analyzer measures quantities such as FM deviation. A receiver sensitivity test needs a calibrated RF level and a specified quality criterion such as SINAD, not merely audible speech. Use attenuators, couplers and loads rated for the expected power; connecting a transmitter directly to a receiver or analyzer can cause damage.
Example: a waveform spans four horizontal divisions at 25 µs/division. Its period is 100 µs and frequency 10 kHz. The vertical scale is irrelevant to this frequency calculation. If the period measurement instead covered two cycles, divide the measured duration by two before inverting.
For faults, establish the symptom and expected behavior, then trace or inject a suitable signal at documented points to find where the response is lost. Separate supply, control, RF and audio paths. Observe ESD procedures for sensitive boards; avoid damaging pads during desoldering; route and secure cables against abrasion, heat and strain. Installation follows applicable codes and the manufacturer’s instructions, not an old fuse rating copied without checking. These are topics 74–81; actual energized work requires competence and an approved safe procedure.
Digital communication and marine data
Simplex and half-duplex arrangements alternate communication direction; full duplex supports simultaneous transmit and receive paths. Time-division multiplexing gives channels separate time slots, while frequency-division multiplexing allocates frequency bands. Frequency hopping changes carriers according to a coordinated sequence; direct-sequence spreading uses a spreading code differently. A codec encodes and decodes information, often including a defined compression method.
Digital signal processing can implement filtering and demodulation after suitable conversion. Sampling does not excuse a poor analog front end: anti-alias filtering prevents unwanted frequencies from folding into the sampled band, and DSP cannot generally recover information lost through clipping or aliasing. A watchdog detects missing software activity; it does not prove the RF path is healthy.
Marine VHF range depends strongly on antenna height, horizon and obstruction. HF operation has different propagation behavior. SITOR ARQ requests retransmission through a return path; forward error correction uses redundancy without that same request cycle. Weather fax reconstructs scan lines, so timing errors can distort image geometry. NAVTEX uses structured identifiers for station, subject and duplicate recognition; consult the National Weather Service explanation.
The NMEA 0183 serial talker/listener links and NMEA 2000 networks are not interchangeable wiring schemes. Check electrical compatibility, wiring, supported messages and serial settings when connecting position data to a DSC radio. Seeing coordinates on the GPS screen does not prove that the radio is receiving fresh position data. Learn the message path and test it using the applicable equipment manuals. These distinctions support topics 82–89.
Radar, satellites and GNSS
Pulsed radar measures a round trip, so range is ct/2. An echo delayed by 40 µs represents 6 km using c = 300 million m/s. Omitting the factor two doubles the answer. Shorter pulses improve range resolution; a narrower antenna beam improves bearing discrimination. Pulse repetition interval limits theoretical unambiguous range, while usable range also depends on transmitter power, propagation, receiver performance and target reflectivity.
A duplexer isolates the sensitive receiver from the transmit pulse when one antenna is shared. Waveguide geometry determines which modes can propagate and their cutoff behavior. Radar clutter controls suppress unwanted echoes but can also hide weak real targets. ARPA and other processing require valid inputs and interpretation; a clean display alone is not proof of a clear sea.
LEO satellites have shorter paths and changing geometry compared with geostationary satellites; motion introduces Doppler and handover considerations. A geostationary satellite’s apparent elevation becomes unfavorable at extreme polar latitudes. Inmarsat-C supplies data messaging and safety functions rather than ordinary voice service; consult the current operator’s Inmarsat-C description. Do not infer a terminal’s features from the provider name alone.
A basic three-dimensional GNSS solution normally solves three position coordinates plus receiver clock bias, using at least four independent satellite measurements. Geometry and signal quality matter as well as satellite count. The topics 90–98 include older satellite examples; current service choices and operational coverage must come from current provider documentation. This bank teaches the enduring functions and distinctions rather than recommending legacy terminal purchases.
Safety is part of the reasoning
Switching off a transmitter does not guarantee its capacitors are discharged. Isolate the relevant sources, follow the documented discharge method and verify the absence of hazardous energy before internal work. Do not use a dark power lamp as proof. A ground-fault interrupter detects an imbalance between outgoing and returning current; it serves a different purpose from an overcurrent fuse and does not replace safe isolation.
RF exposure depends on the operating frequency, power, duty cycle, antenna pattern, distance and access conditions. Neither silence nor an operator license establishes a safe exposure level. Optical fibers can carry invisible radiation: do not look into their ends. Lightning protection, grounding, protective equipment and tool procedures must suit the installation; a single accessory is not a guarantee against every lightning event.
The exam’s safety topics are 99 and 100. For actual RF assessment, consult the FCC RF exposure limits in § 1.1310 and applicable current limits. This article explains why precautions exist; it does not authorize energized work or replace a workplace safety procedure.
A preparation sequence you can check
- Start with Element 1. Explain the difference between distress, urgency and safety; then work through watches, logs, controls and equipment functions. Use the actual rule text for legal details.
- Build the electrical model. Solve units, Ohm’s law, RMS and power problems on paper before selecting an answer. Move to RC behavior, complex impedance and transformer ratios when you can explain each conversion.
- Trace a complete radio. Follow input filtering, mixing, IF selection, detection and audio; then follow a transmitter in the opposite functional direction. Mark where images, overload and distortion arise.
- Add digital logic, power systems, antennas, aircraft and marine equipment. For each block, state its input, output, purpose and likely fault symptom.
- Attempt the GROL study test. For an incorrect answer, write the misconception, work a different example and repeat that topic. A remembered answer letter is weaker evidence than a correct explanation.
- Before booking, obtain the current authorized pool and instructions from the COLEM. Check each official element separately and practice its actual format. Arrange supervised practical training for tasks that cannot be assessed through written answers.
There is no universal preparation duration. Progress when you can explain both the correct method and why plausible alternatives fail. Use the bank’s feedback as a topic checklist, not a prediction of licensing success.
Sources and editorial provenance
Sources checked on 28 November 2026. The two FCC pool files were read through archived official copies; the archive does not certify the latest authorized examination pool. This article, its examples, questions and diagrams are original educational material. Diagrams are explanatory illustrations, not photographs, measured results or equipment wiring instructions.
- FCC: Commercial Element 1 question pool, approved 25 June 2009.
- FCC: Commercial Element 3 question pool, approved 25 June 2009.
- eCFR/FCC: 47 CFR Part 13, retrieved currency 19 November 2026.
- eCFR/FCC: 47 CFR Part 80, retrieved currency 25 November 2026.
- eCFR/FCC: 47 CFR Part 87, retrieved currency 25 November 2026.
- Mariners Learning System: Current GROL examination offering; examiner-specific arrangements.
- FAA: Aeronautical Information Manual, Navigation Aids.
- NOAA/National Weather Service: GMDSS and NAVTEX.
- Inmarsat Maritime: Inmarsat-C service description.